Canada Pumping Monitor

Category:

CanadaComposition of AML135

Product Description

Introduction

Multifunctional Controller (Y=51-99)

Y=1:

Groundwater Sampling Controller

Y=2:

Soil Gas Sampling Controller

Y=3:

Flow Rate and Direction Controller

Water Quality Technical Analysis Parameters

Water Level Technical Parameters

Testing Method Pressure Method
Measurement Range Over 0~100m
Accuracy ≤±0.25% Full Scale
Resolution ≤0.01m

Nitrate Nitrogen Technical Parameters

Testing Method Ion Selective Electrode Method or Optical Method
Measurement Range 0~10mg/L (or 0~100mg/L)
Accuracy ≤±0.1mg/L (or ±5)
Resolution ≤0.1mg/L
Lower Limit of Determination ≤2mg/L
Zero Drift ≤±5%
Span Drift ≤±5%

Nitrite Technical Parameters

Determination Method N-(1-Naphthyl)-ethylenediamine Spectrophotometry
Measurement Range 0~2/10/50 mg/L (expandable)
Lower Limit of Quantification 0.2mg/L
Indicated Error ±5%
Zero Drift ±3%

Chloride Technical Parameters

Measurement Method Ion Selective Electrode Method
Measurement Range 0~500 mg/L (expandable)
Accuracy ±5%
Repeatability ≤5%

Sulfate Technical Parameters

Measurement Method Spectrophotometry
Measurement Range 0~1000mg/L (expandable)
Accuracy ±10%
Repeatability ≤5%

Redox Potential Technical Parameters

Testing Method Electrode Method
Measurement Range -999~999mV
Accuracy ≤±20mv
Resolution ≤1mV

Water Temperature Technical Parameters

Testing Method Electrode Method
Measurement Range -5°C~50℃
Accuracy ≤±0.5℃
Resolution ≤0.1℃

Conductivity Technical Parameters

Testing Method Electrode Method
Measurement Range 0~200mS/cm
Accuracy ≤±2% of Reading
Resolution ≤0.01mS/cm

Heavy Metal - Arsenic Technical Parameters

Measurement Method Voltammetry or Spectrophotometry
Measurement Range 0~2mg/L (expandable)
Accuracy (Indicated Error) ±10%
Zero Drift ±5%
Span Drift ±10%

Cyanide Technical Parameters

Measurement Method Isonicotinic Acid-Barbituric Acid Spectrophotometry
Measurement Range 0~0.5mg/L (more ranges can be expanded)
Repeatability ≤5%
Accuracy ±5%
Zero Drift ±5%

Nitrate Nitrogen Technical Parameters

Measurement Method Spectrophotometry
Measurement Range 0~50mg/L (expandable)
Accuracy ±5%
Zero Drift ±5%

Turbidity Technical Parameters

Testing Method Optical Method
Measurement Range 0~3000NTU
Accuracy ≤±5%
Resolution <1.0NTU

Ammonia Nitrogen Technical Parameters

Testing Method Ion Selective Electrode Method
Measurement Range 0~20mg/L
Accuracy ≤±5%
Resolution ≤0.01mg/L
Lower Limit of Determination ≤0.1mg/L

Heavy Metal - Hexavalent Chromium Technical Parameters

Measurement Method Spectrophotometry
Measurement Range 0~1.0mg/L (expandable)
Accuracy ±5%
Zero Drift ±5%

Fluoride Technical Parameters

Analysis Method Ion Selective Electrode Method
Measurement Range 0~5 mg/L (expandable)
Accuracy ±10%
Precision ≤5%
Zero Drift ±5%
Span Drift ±5%

Iodide Technical Parameters

Measurement Method Ion Selective Electrode Method
Measurement Range 0.0~0.5mg/L (expandable)
Accuracy ±5%
Repeatability ≤5%

PH Technical Parameters

Testing Method Glass Electrode Method
Measurement Range 0~14PH
Accuracy ≤±0.2pH
Resolution ≤0.01PH

Permanganate Technical Parameters

Measurement Method Potassium Permanganate Oxidation-Titration Method
Measurement Range 0~20mg/L, 20~200mg/L (range expandable)
Indicated Error ±5%
Zero Drift ±3%F.S
Span Drift ±3% F.S

Dissolved oxygen electrode technical parameters

Determination Method Fluorometric method;
Measurement Range 0~20 mg/L
Accuracy ≤0.15mg/L
Zero Drift ±0.2mg/L
Span Drift ±0.2mg/L
Indicated Error ±0.3mg/L

Anionic surfactant technical parameters

Measurement Method Spectrophotometry;
Measurement Range 0~5mg/L, adjustable;
Accuracy ±10%
Repeatability ≤5%

Groundwater flow velocity and direction instrument technical parameters

Measurement Method Example image recognition measurement technology
Flow velocity measurement range 0~30mm/s
Flow velocity measurement accuracy: 0.01um/s
Azimuth measurement accuracy: ±1°

Request a Quote