Pumping monitor
+
  • Pumping monitor

AML132-Y

Pumping monitor


Function: Realtime access to all groundwater monitoring Wells in the country,Environmental protection bureaus can monitor any well in the countryin real time and can observe changes in its waterlevel and water quality.
Advantage: Relevant departments of 28 provinces and cities in the National Testing Center of the Ministry of Ecology are used as law enforcement instruments

WhatsApp: 8615830190109


Download Files

INTRODUCTION

Multi-function controller(Y=51-99)

Y=51:

Groundwater sampling controller

Y=52:

Soil vapor sampling controller

Y=53:

The controller of the flow velocity

Technical analysis parameters of water quality

Water level

method: pressure
range: 0~100m or more
accuracy: ≤±0.25%full scale
resolution: ≤0.01m

NO3-N

Method: lon-selective electrode or optical
range: 0~10mg/L(or 0~100mg/L)
accuracy: ≤±0.1mg/L(or±5)
resolution: ≤0.1mg/L
lower limit: ≤2mg/L
zero drift: ≤±5%
range drift: ≤±5%

Nitrite

method: C10H7-NH-CH2-CH2-NH2·HCI Photometry
range: 0~2/10/50 mg/L(extensible)
lower limit of quantification: 0.2mg/L
Indication error: ±5%
zero drift: ±3%

Chloride

method: lon-selective electrode
range: 0~500 mg/L(extensible)
accuracy: ±5%
repeatability: ≤5%

Sulfate

method: spectrophotometry
range: 0~1000mg/L(extensible)
accuracy: ±10%
repeatability: ≤5%

ORP

method: electrode
range: -999~999mV
accuracy: ≤士20mV
resolution: ≤1mV

Conductivity

method: electrode
range: 0~200mS/cm
accuracy: ≤±2%
resolution: ≤0.01mS/cm

As

method: voltammetry or spectrophotometry
range: 0~2mg/L(extensible)
accuracy: ±10%
zero drift: ±5%
range drift: ±10%

Cyanide

method: C6H5N02-C4H4N203spectrophotometry
range: 0~0.5mg/L(extensible)
repeatability: ≤5%
accuracy: ±5%
zero drift: ±5%

NO3-

method: spectrophotometry
range: 0~50mg/L(extensible)
accuracy: ±5%
zero drift: ±5%

Temperature

method: electrode
range: -5°C~50°C
accuracy: ≤±0.5°C
resolution: ≤0.1℃

Ammonia nitrogen

method: lon-selective electrode
range: 0~20mg/L
accuracy: ≤±5%
resolution: ≤0.01mg/L
lower limit: ≤0.1mg/L

Cr6+

method: spectrophotometry
range: 0~1.0mg/L(extensible)
accuracy: ±5%
zero drift: ±5%

Fluoride

method: lon-selective electrode
range: 0~5 mg/L(extensible)
accuracy: ±10%
precision: ≤5%
zero drift: ±5%
range drift: ±5%

iodide

method: lon-selective electrode
range: 0.0~0.5mg/L(extensible)
accuracy: ±5%
repeatability: ≤5%

Turbidity

method: optical
range: 0~3000NTU
accuracy: ≤±5%
resolution: <1.0NTU

PH

method: glass electrode
range: 0~14PH
accuracy: ≤±0.2pH
resolution: ≤0.01PH

Homomethylate

method: KMn04oxidation-titration
range: 0~20mg/L,20~200mg/L(extensible)
Indication error: ±5%
zero drift: ±3% F.S
range drift: ±3% F.S

Dissolved oxygen electrodes

method: fluorescence
range: 0~20mg/L
accuracy: ≤0.15mg/L
zero drift: ±0.2mg/L
range drift: ±0.2mg/L
Indication error: ±0.3mg/L

Anionic surfactants

method: spectrophotometry
range: 0~5mg/L,adjustable
accuracy: ±10%
repeatability: ≤5%

Flow velocity

measure: particle image recognition measurement
flow rate range: 0-30mm/s
flow rate precision: 0.01um/s
direction precision: ±1°

Inquire